DC47-00016A Thermal Fuse Thermostat & DC32-00007A Dryer Thermistor for Samsung & Kenmore DryersDC47 00016A Thermal Fuse & DC32 00007A Thermistor Dryer Sensor Kit Key Features Precision Thermal Monitoring: The DC32 00007A thermistor is an NTC (Negative Temperature Coefficient) sensor that communicates real time temperature data to the control board, ensuring consistent heat levels and preventing fabric damage. High Limit Safety Cut Off: The DC47 00016A thermal fuse acts as a critical safety barrier, immediately cutting power to the heating
DC47-00016A Thermal Fuse & DC32-00007A Thermistor Dryer Sensor Kit
Key Features
- Precision Thermal Monitoring: The DC32-00007A thermistor is an NTC (Negative Temperature Coefficient) sensor that communicates real-time temperature data to the control board, ensuring consistent heat levels and preventing fabric damage.
- High-Limit Safety Cut-Off: The DC47-00016A thermal fuse acts as a critical safety barrier, immediately cutting power to the heating element if temperatures exceed safe operating limits to prevent dryer fires.
- Rapid Response Engineering: Both sensors are designed with low-latency thermal conductivity, allowing the dryer to react instantly to temperature spikes caused by restricted airflow or lint buildup.
- Moisture-Resistant Housing: Encased in high-grade, heat-stabilized polymers and corrosion-resistant metals, these components are built to survive the high-humidity, high-vibration environment of a dryer drum housing.
- Exact Electrical Calibration: Engineered to match original factory resistance (Ohms) specifications, ensuring the control board receives accurate signals for error-free cycle timing and energy-efficient drying.
Replaces / Cross-Reference Part Numbers
- Thermal Fuse (DC47-00016A): AP4201894, PS4205213, WP35001087, 35001087, 2068545, 1122480, L0016A, EAP4205213, EAP11741821, PD00005341
- Thermistor (DC32-00007A): AP4201716, PS4204984, 35001191, DE0007A, N3S1-K41, 2068429, AH2038482, EAP2461163, PS2461163, AP6008688
Compatibility & Fitment
This sensor kit is the primary electronic temperature control set for modern Samsung and Kenmore-branded dryers. Key compatible series include:
- Samsung DV Series: Fits hundreds of models including DV45H7000EW, DV48H7400EW, DV42H5000EW, DV210AEW, DV4006110, and DV50F9A8EVP.
- Samsung DVE/DVG Series: Compatible with both Electric (DVE) and Gas (DVG) versions of the 400, 450, 480, and 500 series.
- Kenmore (402 Series): Fits many 402-prefix models produced by Samsung for Sears (e.g., 402.89032010, 402.99032011).
- Note: These parts are typically located on the Blower Housing or the Heater Duct. Verify your model number to ensure your unit uses the "blue-tipped" thermistor style.
When to Replace
- No Heat at All: The dryer runs and the drum turns, but the air remains cold. This often happens because the DC47-00016A thermal fuse has blown to protect the unit from an overheat condition.
- "tS", "tE", or "HE" Error Codes: Samsung dryers will display these error codes on the console when the control board detects an open circuit or incorrect resistance from the thermistor.
- Long Drying Times: If the thermistor is out of calibration, it may signal the heater to turn off too early, leaving clothes damp even after a full cycle.
- Dryer Shuts Off Mid-Cycle: The unit stops unexpectedly a few minutes into the cycle as the sensors detect a rapid, unsafe rise in temperature.
- Overheating: If the thermistor fails in a "closed" state, the heater may stay on too long, making the top of the dryer cabinet hot to the touch.
Installation Tips
- Safety First: You MUST unplug the dryer. This repair requires accessing the internal blower and heater assemblies, which are connected to high-voltage circuits.
- Access the Sensors: Most technicians access these parts by removing the lower front kickplate or the entire front panel and drum. The thermistor and fuse are usually mounted side-by-side on the blower housing.
- The "Ohm" Check: Before installing, you can test the new DC32-00007A thermistor with a multimeter. At room temperature (77°F), it should read approximately 10,000 Ohms (10kΩ).
- Check Airflow First: If your thermal fuse has blown, it is almost always caused by a clogged dryer vent. Before running the dryer with new parts, clean your exhaust duct to the outside to prevent the new fuse from blowing immediately.
- One Screw Mounting: These parts are usually held in by a single 1/4-inch hex head screw. Be careful not to over-tighten, as the plastic blower housing can strip easily.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy